Page 170 - CITS - Electrician - Trade Practical
P. 170

ELECTRICIAN - CITS




           TASK 2: Record the name plate details

           1  Note down the name plate details of the 3Ф Squirrel Cage Induction Motor and slip ring induction motor.


           TASK 3: Measurement of starting current & running current
           1  Connect the motor as per diagram for starter 1
           2  Trace the connections of power and control circuits.
           3  Set the over load relay current.

           4  Switch on the ICTP.
           5  Start the motor by pressing the start button.
           6  Measure the starting current and running current.
           7  Switch OFF the motor by pressing the stop button.
           8  Switch off the supply and disconnect.

           9  Repeat steps 1 to 2 for starers 2 to 6 as in Table 1
           10 Tabulate currents in Table 1
                                                         Table 1


                 Sl.No                Starter            Starting current (A)   Nol load running current (A)
                   1          DOL

                   2          Semi-automatic star delta
                   3          Automatic star delta
                   4          Manual star delta

                   5          Rotor resistance starter
                   6          Auto transformer starter






































                                                           153

                                     CITS : Power - Electrician & Wireman - Exercise 70
   165   166   167   168   169   170   171   172   173   174   175