           TASK 2: Bright lamp method
           1  Make the connections as per the circuit diagram for bright lamp method. Fig 2

           2  Switch on the supply and run the prime mover and alternator.
           3  Switch ON and vary the DC excitation supply to build rated voltage of alternator.
           4  Check the phase sequence of the bus bar and incoming machine using phase sequence indicator.
           5  Connect the phases of incoming machine in ICTP so as to match the phase sequence of busbar.

           6  Adjust the voltage of incoming alternator to match that of busbar by varying excitation.
           7  Adjust the frequency of incoming alternator to match that of busbar by varying speed of prime mover.
           8  Vary the prime mover to get the dark condition of the lamp connected directly between two phases and to get
              the equally dim condition of lamps interposed between two phases.

           9  Close the synchronizing switch when the condition at above step is met.