Page 224 - CITS - Electrician - Trade Practical
P. 224

ELECTRICIAN - CITS




           TASK 3: Perform winding of armature

           1  Select the winding wire according to the original winding and mount the spool on a stand.

              For sumeet mixer use winding wire of size 30SWG.
           2  Insert a guide paper in the identified slots in which the coil is to be placed. (Fig 9)

              For the sumeet mixer, taken as an example, we have

              Total number of slots            = 12
              Segments                         = 24
              Winding wire                     = 30 SWG
              Number of coil sides in each slot  = 4
              (2 coil sides are looped together and the loops are connected to the segments)

              Number of turns in each coil = 36 turns identified slot pitch 1-6.

           3  Place a guide paper in slots 1 and 6. (Fig 9)
           4  Hold the armature in hand. (Fig 10)



















              Large size armatures are to be supported by stands (horses during winding). (Fig 11)






















           5  Wind the armature by hand placing one end of the coil side in slot No.1 and the other in slot No.6

           6  Count 36 tuns and then make a longer loop.
              Do not make mistakes in counting. Wrong number of turns will result in unbalanced armature.

           7  Make another 36 turns in the same solts (1 and 6) by holding the loop with your fingers of the hand.




                                                           207