Page 233 - CITS - Electrician - Trade Practical
P. 233

ELECTRICIAN - CITS




           23 Insert right coil side of first coil, continued by other coils
           24 Repeat previous 2 steps till completion of insertion of all coils
           25 Tie overhang with cotton tape and press carefully near to the core for preventing obstruction to end cover and
              use nylon hammer to shape coils.
           26 Insert slot wedges to tightly pack the coil
           27 Connect group connections of each phase, solder and sleeve them.

           28 Tie the joints to overhang and make phase connections
           29 Measure the resistance of the winding
           30 Test the insulation resistance between windings, windings and body
           31 Varnish the windings

           32 Run the motor, measure currents and asses performance
           For the double layer winding, insert left coil-sides of coils till the winding pitch.
           Right side of first coil is to be inserted above the left side coil of next pole as per winding diagram.
           Single layer winding example :
           star connected, three phase , 50Hz, 1450rpm, squirrel cage induction motor having 24 slots

























































                                                           216

                                    CITS : Power - Electrician & Wireman - Exercise 91
   228   229   230   231   232   233   234   235   236   237   238