Dismantle, replace and assemble FRL unit
Objectives: At the end of this exercise you shall be able to
• overhaul FRL unit
• mount and read pressure on the pressure gauge.
Job Sequence
• Overhauling a filter of FRL unit and Lubricator.
• Drain the water from the filter unit.
• Hold the FRL unit in a bench vice in a horizontal position between soft jaws.
• Drain water from lubricator, by rotating drain plug.
• Hold the filter bowl with hand and unscrew it.
• Do not use pipe wrench since bowl (mostly of plastic) may break/damage.
• Use a spanner and remove the filter insert.
• Rinse the filter in clean kerosene.
• Blow the inner side of filter using compressed air.
• Rinse the bowl in soap solution and dry it with clean cloth.
• Place the filter insert and tighten the nut.
• Screw the bowl to the housing.
• Confirm the drain plug is in closed condition.
161