            Dismantle, replace and assemble FRL unit


           Objectives: At the end of this exercise you shall be able to
           •   overhaul FRL unit
           •  mount and read pressure on the pressure  gauge.







































            Job Sequence

           •  Overhauling a filter of FRL unit and Lubricator.
           •  Drain the water from the filter unit.

           •  Hold the FRL unit in a bench vice in a horizontal position between soft jaws.
           •  Drain water from lubricator, by rotating drain plug.
           •  Hold the filter bowl with hand and unscrew it.
           •  Do not use pipe wrench since bowl (mostly of plastic) may break/damage.

           •  Use a spanner and remove the filter insert.
           •  Rinse the filter in clean kerosene.
           •  Blow the inner side of filter using compressed air.
           •  Rinse the bowl in soap solution and dry it with clean cloth.
           •  Place the filter insert and tighten the nut.
           •  Screw the bowl to the housing.

           •  Confirm the drain plug is in closed condition.












                                                           161