P. 143

MECHANIC DIESEL - CITS


                                                            .
           2  Connect the red clip to the plus pole of the battery and the black to the minus pole.
           3  Connect the inductive pickup surrounds all  of the wires from the battery negative terminal.
           4  Note down the battery ampere hour rating and CCA rating from the battery label.

           5  Load the battery by Turning the load control knob until the ammeter shows three times the Ampere hour rating
              or one –half of its CCA rating.
           6  Maintain the load for maximum 15 seconds.

           7  Note the voltmeter reading. If reading shows 9.6Volts or more battery is good,9.5V or less the battery is
              defective and needs replacement.
           8  Disconnect the load tester.