Page 329 - CTS - Mechanic Diesel - TP
P. 329
MECHANIC DIESEL - CITS
Table 2
S.No. Connection Condition of lamp
between
1 R and N
2 Y and N
3 B and N
4 F1 and F2
Fig 1
3 Check the continuity between F and F (Fig 2) and enter the finding in Table 2.
1 2
Fig 2
TASK 3: Measure insulation resistance between windings
1 Connect one prod of the Megger to any one of the terminals R,Y,B,N and the other prod to the terminal F1 or
F2 as shown in Fig 3.
Fig 3
312
CITS : Automotive - Mechanic Diesel - Exercise 18.2