           damaged. In the condenser, two leaves made of tin or aluminum are wrapped in layers, between which wax paper
           is applied as insulation. These leaves are kept closed in a case.
           When C.B. Points rotation opens to break the circuit, in that case C.B. Spark is generated in the points, due to
           which C.B. The points start burning and the formation of high tension current is hindered. In case of high tension
           current flowing in a low tension circuit, condensers store maximum current inside them. The condenser and its
           structure are shown in the figure. It consists of lead or aluminum coils, which are separated from each other. One
           end of the coil is connected to the condenser terminal and the other end is connected to the condenser case.














           5  Ignition Switch Ignition Switch
           The ignition switch is fitted on the panel board between the battery and the ignition coil. It connects and separates
           the primary circuit from the battery.
           6  Contact Breaker
           To generate high voltage in the secondary winding of the coil, the contact breaker connects and disconnects the
           primary circuit at certain time intervals. There are two number of contact breaker points, one of which is directly
           fitted on the base plate and the other is insulated and operated by a rotating arm.

           2  Magneto ignition system
           Magneto ignition system has its own current generating device, therefore battery is not required.
           The arrangement of the magneto ignition system for four cylinder S.I. Engine is shown in figure.



















           Essential components of the system

           1  Electrical generator
              An electrical generator with permanent field magnets and rotating armature which produces an alternating
              current.

           2  Induction coil
              An induction coil with primary and secondary windings being wound on the armature.
           3  Contact breaker
              A contact breaker to interrupt the generator primary circuit and the condenser.
           4  Distributor
              A distributor to distribute high tension current to spark plugs.



                                                           233