Page 45 - CITS - Welder - Trade Theory
P. 45

WELDER - CITS






















           Working Principle

           Two welding cables are attached with the output terminals. One is for the electrode and the other is for earth or
           job.
           The transformer may be air – cooled or oil- cooled.

           The AC main supply (220 -440 volts) is connected to the primary winding which produces a magnetic lines of
           force in the iron core.
           The magnetic lines of force affects the secondary winding and induces high ampere – low voltage welding supply
           in it.
           The voltage at the primary coil is reduced in the secondary coil depending on the ratio of the No. of turns in the
           primary to that of the secondary.
                                                                                       Voltage at primary coil X No. of turns in the secondary
                         Voltage at secondary coil =
                                                                                    No of turns in the primary