           EXERCISE 73 : Measure speed, torque, slip, current,
                                     power,PF


            Objectives

           At the end of this exercise you shall be able to:
           •  carry out the direct loading test on motor with brake arrangement
           •  calculate the Torque developed by motor from the readings of the spring balance
           •  calculate the power factor of the motor .

           Requirements
           Tools/Instruments                                   Equipments/Machines
           •  Combination pliers 150mm         -1 No.          •  3Ф Squirrel cage Induction
           •  Screw driver 100mm            -1 No.                Motor 5 HP,1440rpm               -1 No.
           •  D.E. spanner set 20mm         -1 Set.            •  DOL starter 5 HP/440V            -1 No.
           •  Electrician knife 75mm        -1 No.             •  ICTP 32A/440V                    -1 No.
           •  Test lamp 60W                 -1 No.
           •  Voltmeter 0 – 500V MI         -1 No.
           •  Ammeter 0 – 25A MI            -1 No.
           •  Wattmeter 500V,5/10A, UPF     -2 Nos.
           •  Power factor meter 500V,5/10A,  -1 No.

            Procedure

           TASK 1: Carry out the direct loading test on motor with brake arrangement

           1  Note the name-plate details of the squirrel cage induction motor
           2  Select the voltmeter, ammeter and wattmeter range suiTable to the specification given in name-plate details.
           3  Make connection as per circuit diagram. (Fig 1)


              Fig 1






































                                                           160