Page 184 - CITS - Electrician - Trade Practical
P. 184

ELECTRICIAN - CITS


                                           MODULE 13: Synchronous Machines


           EXERCISE 76 :   Install an alternator and identify various

                                       parts and terminals of the same

            Objectives


           At the end of this exercise you shall be able to:
           •  identify the prime mover and alternator mounting requirements
           •  identify terminals of alternator
           •  wire up the alternator and prime mover to a panel.

           Requirements

           Tools/Instruments
           •  Combination pliers 150mm         -1 No.          •  Test lamp 60W                    -2 Nos.
           •  Side cutting pliers 150mm     -1 No.             •  Multimeter Digital               -1 No.
           •  Heavy duty screw driver 250mm  -1 No.            •  Meggar 500v                      -1 No.
           •  Screw driver 100mm, 150mm        -1No. each.     Equipments/Machines
           •  D.E. spanner set  5 – 30mm    -1 No.
           •  Electrician knife 75mm        -1 No.             •  Alternator 5 KVA Alternator      -1 No.
                                                               •  DC Shunt motor 7.5HP 230V        -1 No.
            Procedure

           TASK 1: Identify the prime mover and alternator mounting requirements
           1  Record the name plate details of Alternator and AC induction motor [Depending on the availability of machines
              available at lab, instructor need to modify the details of prime mover]

                         Sl. No             Description                        Value
                           1.                 Make
                           2.                 Model
                           3.             Serial number
                           4.              No of phases
                           5.                Voltage
                           6.                 Power
                           7.               Frequency
                           8.                Current
                           9.            Class of insulation
                          10.            Excitation voltage
                          11.            Excitation current
                          12.             Protection class

           2  Identify the frame sizes of motor and alternator.  Fig 1
           3  Verify the mounting hole dimensions  of  the
              motor – alternator set and prepare a template
              for mounting Fig 1
           4  Mount foundation bolts for coupled motor
              alternator set
           5  Mount the motor generator assembly on level
              ground by foundation bolts erected.



                                                           167

 CITS : Power - Electrician & Wireman - Exercise 75
   179   180   181   182   183   184   185   186   187   188   189