           TASK 6:
           1  Dismantle the Table fan.
           2  Identify and specify the parts of the fan.
           3  Draw the circuit diagram and neat sketch of the fan.

           4  Check the windings of the fan with multimeter.
           5  Measure the resistance of the windings.
           6  Identify the starting and running winding.
           7  The starting winding is having comparatively higher resistance.
           8  Trace the internal connections of the Table fan.

           9  Rectify the fault of the fan, if any. Refer pedestal fan trouble shooting points.
           10 Replace the capacitor with an identical good capacitor, if the fan is not running.
           11 Re assemble the fan properly.
           12 Check the operation of the fan.