                  Sl. No                       Description                               Value
              Charge controller
              1.              Make

              2.              Maximum Current Output
              3.              Nominal Battery Voltage
              4.              PV Open Voltage
              5.              Maximum PV Array Power under STC

              6.              Technology: PWM / MPPT
              7.              MPPT Voltage Range (For MPPT Controllers)
              Battery
              1.              Make

              2.              Battery Type: Lithium-ion / Lead-acid/Lithium iron
                              phosphate (LiFePO4)
              3.              Capacity (Ah)**:
              4.              Voltage
              5.              C rating

              Solar panel
              1.              Make
              2.              Type: Mono /Poly /PERC
              3.              Voltage at Maximum Power Point (Vmpp):

              4.              Current at Maximum Power Point (Impp):
              5.              Dimensions and Weight
              6.              Open circuit voltage Voc
              7.              Short Circuit current Isc



           TASK 2:

           1  Mount the solar panels with orientation to south and with inclination angle equivalent to latitude of the location
           2  Wire  the  charge  controller  to  battery  first  and  then  the  solar  panel  through  disconnect  switch  as  per  the
              terminals provided in charge controller
           3  Keep the switch in OFF position.

           4  Inspect the connections.



           TASK 3:

           1  Switch On the circuit.
           2  Demonstrate illumination of the load.
           3  Note the voltage and currents at panel side and load side of charge controller with different load conditions in
              Table 1
           4  Observe the variation of current with variation of panel mounting angle.
           9  Observe the variation of current with variation of panel mounting angle