Page 196 - Electrician - TT (Volume 2)
P. 196

ELECTRICIAN - CITS                                                                 ELECTRICIAN - CITS




           Calculation of electrical degrees required for phase splitting

           Total electrical degrees   = 180 x Total number of poles
                                     = 180x4= 720 electrical degrees
           Degrees/slot       = 720/24 = 30 electrical degrees
           No. of slots required for 90 electrical degrees dis-placement  between  main  and  starting  winding = 90/30 = 3
           slots.
           Hence if the main winding starts in, say, slot number one, then the starting winding should be started in 1+3 = 4th
           slot.

           Computing the above information in a winding table we have Table 2.

                                                         Table 2
                                                      Winding table

                                                     Slot position for poles

                             Winding        I pole      II pole     III pole    IV pole
                             Main           1 - 6       7 - 12      13 - 18     19 - 24

                                            2 - 5       8 - 11      14 - 17     20 - 23

                             Starting       4 - 9       10 - 15     16 - 21     22 - 3


           Remembering whole coil connection the connection diagram is to be drawn as shown in Fig 4.
           Remember ‘S’ is for starting and ‘E’ for end connection.
           Based on the winding table the developed diagram is drawn as shown in Fig 5.


              Fig 4                                            Fig 5





















           Example 2 : Prepare the winding table, draw the connection and developed diagrams for a single phase, 4-pole,
           whole coil connected capacitor motor having 36 slots 28 coils (16 coils for main and 12 coils for the starting
           winding).
           Coil per group in main winding 16/4=4 coils/group/poles
           Coil per group in starting winding 12/4 = 3 coils/group/poles

                                              Number    of   slots  36
                                   Pole   pitch              -    1         1   -    9      -    1  8
                                              Number   of   poles  4




 182                                                       183

 CITS : Power - Electrician & Wireman - Lesson 86-92  CITS : Power - Electrician & Wireman - Lesson 86-92