That all connector have a gender male and female. The male refers to the connector that plugs and the female
refers to the connector that are plugged into, connectors also have a polarity-polarity sensitive connectors are
designed to be plugged in a specific orientation while polarity insensitive connector can be plugged and unplugged
in any direction
To prevent inductive coupling, keep the signal wire pairs twisted all the way up to the terminals.
1 Strip the outer insulation of the cable and ground the bare shield 360 degrees under the clamp.
2 Connect the conductors to the correct control terminals.
3 For double-shielded cables, twist also the grounding conductors of each pair in the cable together and connect
the bundle to terminal SCR (1).
4 Mechanically attach the control cables on the outside of the drive
Result:
AC drives reduce thermal and mechanical stresses on motors and belts. AC drive installation is as simple as
connecting the power supply