           3  Trace the line paths between the first or the closest component connected to each terminal pads.The circuit
              diagram shows that there are coil filter in both lines, connect the tester across each coil terminal leds, your not
              just checking the lines here but also checking the the coil as well.


















           4  Now the next step is to leave behind the line paths between the coil to the EMI-Filter for it is uncheckable
              beyond that paths for the EMI- filter is an IC. you need to remove it first before you can check on that lines,
              which  will  be  done  later  at  the  last  steps  of  procedures.  Now  next  to  move  on  to  the  opening  lines  and
              component where the test probe can connect with, the two filter capacitors and both coils which are an open
              path where you can connect the test probe on it. now connect or attach both probes at the end of each line
              indicated in red.




















           5  Now check the remaining open path which is the Resistor, you can’t check the line paths on those area for it
              ends up connected to Retu IC. So just then proceed to check its resistance value instead.









                                                           239

                                   CITS : E & H - Electronics Mechanic - Lesson 130 - 145