Page 164 - CITS - Fitter Trade Practical - Volume -2
P. 164
FITTER - CITS
Check the bend for squareness use a set square as shown. (Fig 9)
Check level of former and first leg (90o bend) with spirit level by placing spirit levels as shown in Fig 10.
Check the angle of bend and radius using standard template. (Fig 11)
149
CITS : C G & M - Fitter - Exercise 86 - 88