Page 205 - CTS - Mechanic Diesel - TP
P. 205
MECHANIC DIESEL - CITS
Eg.
501 5018
501 5017
501 5019
Mean Value
501 5018
16 Press again the AUTO key to start the actual test.
17 Actual test procedure:
• Note down the value1 appears on the digital display indicating that the unites ready for the first free
acceleration test during the next 5 sec the gate to the micro processor or memory is open and scans for the
peak opacity and stores it.
• Depress the accelerator pedal smoothly and completely and keep it there.
• The engine will be accelerated from low idle to high idle (govern or cut off speed).
• Keep the engine at high idle for about 5 sec and then release the accelerator pedal. The gate to the
memory of the micro processor is closed for 3 sec after the initial 5 sec have elapsed. The peak value of
this test is indicated at the digital display.The flashing of the LED at AUTO key indicates the next cycle can
start.
• Press AUTO-key. The value 2 indicates the readiness of the unit for the second free acceleration test.
• Continue as pre scribed above.
• Repeat procedure until 3 valid free acceleration tests have been performed.
• Press AUTO again For 3 sec (“....”) appears then the mean value of the 3 valid test peak values is indicated
and the test report is printed.
Be interrupted by not pressing the indication test for minimum 30 sec sand thus gives a protocol printout indicating
the results of the tests taken.
18 As the test completes you will again get the printout of the actual readings. Eg.
Smoke meter
Pre scr.value:2.45m-1 As per
CMVR
Date:Mon,17-May-
2004 Time:02:53
Vehicle:……………
Model:……………...
TEST CONDITIONS
Voltage: OK
SmokeTemp.: 40°
C
RPM RPM T HSU K
MIN Max °C % m-1
*501 5018 69 18.5 0.47
*501 5017 69 19.3 0.49
*501 5018 69 19.1 0.49
Valid Readings
Smoke Mean Value
18.9%0.47m-1
188
CITS : Automotive - Mechanic Diesel - Exercise 12.2