Page 128 - CITS - Electrician - Trade Practical
P. 128
ELECTRICIAN - CITS
MODULE 10: Illumination,Connection of
Electrical Lights
EXERCISE 54 : To connect and test different types
Electric lamps
Objectives
At the end of this exercise you shall be able to:
• identify the different types of electric lamps, their construction & ratings
• connect and test all kinds of electric lamps
• check the illumination of lamps.
Requirements
Tools/Equipments/Instruments
• Combination Plier 165mm, • HPMV lamp fitting with ballast,
insulated -1 No. capacitor 150 W, 230 V -1 No.
• Screw Driver 150mm, insulated • HPSV lamp fitting with ballast,
stem -1 No. igniter 150 W, 230 V -1 No.
• Neon Tester 75mm, 500 V -1 No. • Halogen lamp fitting 500 W, 230 V -1 No.
• Electrician knife Insulated -1 No. • CFL light fitting 36 W, 230 V -1 No.
• Multi meter Digital, 3 digit -1 No. • LED Bulbs Assorted rating -3 No’s.
1/2
Materials/Components • LED tube light with driver
• PVC copper wire 1.5 sq.mm -as reqd. 22 W, 230 V -1 No.
• Incandescent lamps Assorted • LED recess type fitting with
rating -3 No’s. driver 36 W, 230 V -1 No.
• Fluorescent tube light fitting with
choke 40 W, 230V -1 No.
Procedure
TASK 1: Identify the different types of lamps
1 Draw the circuit diagram of connection of different types of lamps.
2 Identify the different types of electric lamps, their construction and ratings.
3 Test the continuity of lamps and ballast with test lamp.
TASK 2 : Connect and test all types of lamps
1 Connect and test the incandescent lamps of different wattage and check the illumination.
2 Make the connection of gas discharge lamps - HPMV lamp & HPSV lamp as per circuit diagram.
3 Connect gas discharge lamps to the supply, measure the starting & running current and illumination.
4 Make the connection of fluorescent tube light as per circuit diagram.
5 Connect the fluorescent tube light to the supply and check the illumination.
6 Connect the halogen lamp and the check the brightness.
7 Connect all types LED bulbs, tube lights, recess fittings and check the illumination.
Safety precautions:
1 Handle the electric lamps carefully and do not drop.
2 Do not make wrong & loose connections.
3 Check the ballast before connecting gas discharge lamps.
111