Page 285 - CITS - Electrician - Trade Practical
P. 285

ELECTRICIAN - CITS




                                                     Test procedures

               Components                                Test                                  Results
            Transformer
                                1  Remove wire leads.

                                2  Measure resistance. (ohm meter scale: Rx1)
                                   •  Primary winding
                                   •  Secondary winding
                                   •  Filament winding
                                3  Measure resistance. (ohm meter scale: Rx1000)
                                   •  Primary winding to ground

                                   •  Filament winding to ground

                                                                                        Approx. 0.3 to 0.5 ohms

                                                                                        Approx. 65 to 120 ohms
                                                                                        0 ohm


                                                                                        Normal: Infinite
                                                                                        Normal: Infinite
            Magnetron           1  Remove wire leads. Install the magnetron  seal in the
                                   correct position. Check that the seal is in good condition.
                                2  Measure resistance. (ohm meter scale: Rx1)
                                   •  Filament terminal
                                3  Measure resistance. (ohm meter scale: Rx1000)
                                   •  Filament to chassis










                                                                                        Normal: Less than 1 ohm


                                                                                        Normal: Infinite
            Capacitor           1  Remove wire leads.
                                2  Measure resistance. (ohm meter scale: Rx1000)

                                   •  Terminal to terminal                              Normal
                                                                                        Momentarily    Infinite
                                                                                        and then soon reach 10
                                                                                        mega. ohms
                                   •  Terminal to case                                  Normal: Infinite.











                                                           268

                                    CITS : Power - Electrician & Wireman - Exercise 103