Page 285 - CITS - Electrician - Trade Practical
P. 285
ELECTRICIAN - CITS
Test procedures
Components Test Results
Transformer
1 Remove wire leads.
2 Measure resistance. (ohm meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
3 Measure resistance. (ohm meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
Approx. 0.3 to 0.5 ohms
Approx. 65 to 120 ohms
0 ohm
Normal: Infinite
Normal: Infinite
Magnetron 1 Remove wire leads. Install the magnetron seal in the
correct position. Check that the seal is in good condition.
2 Measure resistance. (ohm meter scale: Rx1)
• Filament terminal
3 Measure resistance. (ohm meter scale: Rx1000)
• Filament to chassis
Normal: Less than 1 ohm
Normal: Infinite
Capacitor 1 Remove wire leads.
2 Measure resistance. (ohm meter scale: Rx1000)
• Terminal to terminal Normal
Momentarily Infinite
and then soon reach 10
mega. ohms
• Terminal to case Normal: Infinite.
268