ELECTRONICS MECHANIC - CITS





























                                                            a:  distance between the top of the heating length and
                                                               the bath level.
                                                            b:  distance between the sheath or the heating length
                                                               and the furnace wall.
                                                            c:  distance between  the end of the sheath and the
                                                               bottom of the tank or the walls.

                                                            d:  distance between the sheath or the heating length
                                                               and the furnace wall.








                                                      Minimum distance to be respected
             Immersion heater
                 position
                                     a (mm)              b (mm)              c (mm)              d (mm)


            Vertical Fig 1              50                 100                 50                   -
            Tilted Fig 2                50                 100                 50                 100

            Horizontal Fig 3           100                 100                 50                 100

           Distance between two immersion heaters