              Note:- Instructor should check the connections properly
              Instructor can set the pressure as per the requirement

           B  Electric Connection
           1  Connect the NO contact (contact no.3) of the Push button switch to 24V of the power supply.
           2  Connect another point of the NO contact (contact no.4) of the Push button switch to A1 of the Relay coil.

           3  Connect A2 of the Relay coil  to 0V of the power supply.
           4  Connect the NO contact (contact no.3) of the Relay to 24V of the power supply.
           5  Connect another point of NO contact (contact no.4) of the Relay to Solenoid coil.
           6  Connect another point of the Solenoid coil to 0V of the power supply.

           7  Get the connection checked by the Instructor.
           8  Switch on the Air supply.
           9  Switch ON 24V DC power supply.
           10 Observe the movement of double acting cylinder by press / release the push button switch and observe the
              speed variation of the Double acting cylinder by open / close the throttle valve.
           11 Get the result checked by the Instructor.