Page 280 - Electronic Mechanic - TP - Volume - 2
P. 280

ELECTRONICS MECHANIC - CITS




              Note:- Instructor should check the connections properly
              Instructor can set the pressure as per requirement
              Instructor should check the relay coil connections

           B  Electric Connection

           1  Connect the NO contact (contact no.3) of the Push button switch to 24V of the power supply.
           2  Connect another point of the NO contact (contact no.4) of the Push button switch to A1 of the Relay coil.
           3  Connect A2 of the Relay coil to 0V of the power supply.
           4  Connect the NO contact (contact no.13) of the Relay to 24V of the power supply.

           5  Connect another point of NO contact (contact no.14) of the Relay to the A1 of the Relay coil.
           6  Connect the NO contact (contact no.23) of the Relay to 24V of the power supply.
           7  Connect another point of NO contact (contact no.24) of the Relay to the Solenoid coil.
           8  Connect another point of the Solenoid coil to 0V of the power supply.
           9  Get the connection checked by the Instructor.
           10 Switch on the Air supply.

           11 Switch ON 24V DC power supply.
           12 Observe the movement of single acting cylinder by press / release the push button switch.
           13 Get the result checked by the Instructor.


















































                                                           263
                                    CITS : E & H - Electronics Mechanic  - Exercise 195
   275   276   277   278   279   280   281   282   283   284   285