6 Connect another Output port (Port No.4) of the 5/2 Solenoid valve to the Input (Piston head end side) of the
Double Acting Cylinder
7 Fix the Limit switch 1 at home position of the Cylinder piston Rod.
8 Fix the Limit switch 2 at extreme end position of the Cylinder piston Rod.
Note: Instructor should check the connections properly
Instructor can set the pressure as per requirement
Check the Limit switch position
B Electric Connection
1 Connect the NO contact (contact no.3) of the Push button switch (PB) to 24V of the power supply.
2 Connect another point of NO contact (contact no.4) of the Push button switch (PB) to the NO contact (contact
no.4) of the Limit Switch 1.
3 Connect Common contact (contact no.1) of the Limit Switch1 to A1 of the Relay coil (K1).
4 Connect A2 of the Relay coil(K1) to 0V of the power supply.
5 Connect the NO contact (contact no.3) of the Relay (K1) to 24V of the power supply.
6 Connect another point of NO contact (contact no.4) of the Relay (K1) to Solenoid coil Y1.
7 Connect another point of the Solenoid coil Y1 to 0V of the power supply.
8 Connect the NO contact (contact no.4) of the Limit Switch 2 to 24V of the power supply.
9 Connect Common contact (contact no.1) of the Limit Switch 2 to A1 of the Relay coil (K2).
10 Connect A2 of the Relay coil(K2) to 0V of the power supply.
11 Connect the NO contact (contact no.3) of the Relay (K2) to 24V of the power supply.
12 Connect another point of NO contact (contact no.4) of the Relay (K2) to Solenoid coil Y2.
13 Connect another point of the Solenoid coil Y2 to 0V of the power supply.
14 Get the connection checked by the Instructor.
15 Switch on the Air supply.
16 Switch ON 24V DC power supply.
17 Observe the oscillation motion of the Double acting cylinder by press / release the PB
18 Get the result checked by the Instructor.
261
CITS : E & H - Electronics Mechanic - Exercise 194