Page 273 - Electronic Mechanic - TP - Volume - 2
P. 273

ELECTRONICS MECHANIC - CITS



           EXERCISE 191: Construct and control a double  acting

                                      cylinder using series parallel circuits

            Objectives

           At the end of this exercise you shall be able to
           •  select the components to construct and control the Double Acting Cylinder using series and parallel circuits
           •  construct the circuit on trainer board as per the diagram
           •  check the function of the circuit.

           Requirements


           Tools/ Materials
           •   Pneumatic trainer board       - 1 No.           •   5/2 DC single solenoid valve   - 1 No.
           •   Digital multimeter with probes   - 1 No.        •  FRL                             - 2 Nos.
           •  Regulated DC power                               •  Push button switch              - 1 No.
              supply 24V/2A                 - 1 No.            •  Relay                           - as reqd.
           •   Pneumatic Source             - 1 No.            •  PU Tube                         - as reqd.
           •   Double Acting Cylinder                   - 1 No.  •  Connecting Cables


           Procedure
           TASK 1:  Select the components to construct and control a Double Acting Cylinder using series and
                   parallel circuits
           1  Select the components to construct the circuit  using ISO 1219 symbol.
           2  Check the DC supply by using multi meter


           TASK 2a & 2b :Construct the circuit and control the a Double Acting Cylinder using series and parallel
                         circuits
           A  Pneumatic Connection
           1  Connect the Compressor to the FRL
           2  Set the FRL for 6 bar
           3  Connect the FRL to the Manifold
           4  Connect input port (Port No.1 or P) of the 5/2 Solenoid valve to the Manifold.

           5  Connect Output port (Port No.2) of the 5/2 Solenoid valve to the Input (Piston Rod end side) of the Double
              Acting Cylinder
           6  Connect another Output port (Port No.4) of the 5/2 Solenoid valve to the Input (Piston head end side) of the
              Double Acting Cylinder

              Note: Instructor should check the connections properly
              Instructor can set the pressure as per  requirement


           B  Electric Connection – Parallel Operation
           1  Connect the NO contact (contact no.3) of the Push button switch1 (PB1) to 24V of the power supply.
           2  Connect another point of NO contact (contact no.4) of the Push button switch1 (PB1)  to A1 of the Relay coil.
           3  Connect the NO contact (contact no.3) of the Push button switch 2 (PB2) to 24V of the power supply.
           4  Connect another point of NO contact (contact no.4) of the Push button switch 2 (PB2)  to A1 of the Relay