The following illustration shows an example of the SINAMICS V90 servo Commissioning purpose when the servo
drive is powered on for the first time, you can perform a test run with the BOP or the engineering tool SINAMICS
V-ASSISTANT to check:
• Whether the mains supply has been connected correctly.
• Whether the 24 V power supply has been connected correctly.
• Whether the cables (power cable, encoder cable, and brake cable) between the servo drive and the servo
motor have been connected correctly.
• Whether the motor speed and direction of rotation are correct.
Prerequisite:
• The servo drive is connected to the servo motor without load.
• No PLC is connected to the drive system.
Result: Thus the Connection of servo motor with SINAMICS V90 servo drive was successfully established.
354
CITS : E & H - Electronics Mechanic - Exercise 238