Page 371 - Electronic Mechanic - TP - Volume - 2
P. 371

ELECTRONICS MECHANIC - CITS




           The following illustration shows an example of the SINAMICS V90 servo Commissioning purpose when the servo
           drive is powered on for the first time, you can perform a test run with the BOP or the engineering tool SINAMICS
           V-ASSISTANT to check:
           •  Whether the mains supply has been connected correctly.
           •  Whether the 24 V power supply has been connected correctly.
           •  Whether the cables (power cable, encoder cable, and brake cable) between the servo drive and the servo
              motor have been connected correctly.
           •  Whether the motor speed and direction of rotation are correct.
           Prerequisite:
           •  The servo drive is connected to the servo motor without load.
           •  No PLC is connected to the drive system.

           Result: Thus the Connection of servo motor with SINAMICS V90 servo drive was successfully established.
































































                                                           354
                                    CITS : E & H - Electronics Mechanic  - Exercise 238
   366   367   368   369   370   371   372   373   374   375   376