Page 249 - CTS - Mechanic Diesel - TP
P. 249

MECHANIC DIESEL - CITS


                                                    MODULE 15: Diesel Fuel System


           EXERCISE 15.1: Maintenance and Over checking of FIP

                                       test bench


            Objectives

           At the end of this exercise you shall be able to
           •  ensure that the test bench is in good condition so that accurate and repeatable readings are obtained.
           •  do maintenance of FIP test bench
           •  rectify the FIP test bench problems.

           Requirements

           Tools/Instruments                                   Materials
           •  Trainee’s toolkit                - 1 No.         •  Tray                            - as reqd.
           Equipments                                          •  Cottoncloth                     - as reqd.
                                                               •  Kerosene                        - as reqd.
           •  Fuel Injection pump test bench   - 1 No.         •  Diesel                          - as reqd.
           •  Master pump with adaptors                - 1 No.  •  SoapOil                        - as reqd.
           •  Hand tachometer                  - 1 No.         •  EngineOil                       - as reqd.
           •  Reference manometer 0-6 kgf/cm²     - 1 No       •  Calibration oil                 - as reqd.
           •  Spare test nozzle                      - 6 Nos.
           •  Spare high pressure pipes        - 6 Nos.
           •  Reference manometer 0-6kgf/      - 1 No.

            Procedure





























           Maintenance
           Every week maintenance
           •  Test injectors: Test the injectors on an over checked nozzle tester for the various functional parameters viz.
              seat tightness, spray pattern, atomisation and opening pressure. If found unsatisfactory;
           Clean nozzle, sieve/bar filter in the inlet connection.
           Repeat functional tests
           If still unsatisfactory, replace complete set of test nozzles .Reset opening pressure to: