Page 253 - CTS - Mechanic Diesel - TP
P. 253

MECHANIC DIESEL - CITS




                                  Fig 2




















                                        Assembly of protective cover and dial indicator


           Set the control rack to 9 mm and fix it by control rack travel measuring device. Check the following readings

            RPM                              1400                             400

            Slider travel (mm)               71-75                            15-18

           If the readings are not obtained, adjust the maximum speed spring tension by adjusting nut (the threaded bolts
           should evenly be projected on each side of the flyweight and the projection should not be more than 2.5. mm or
           less than ‘0’ from adjusting nut).
           If the reading are still not obtained, replace spring seat/washer/max. speed springs.


                                  Fig 3



















                                               Measuring the projection of bolt


           3  Sliding bolt position.
           Remove the protective cover and assemble the original cover. Fix control lever in reverse position. Control Lever
           in stop position, adjust control rack travel measuring device to ‘0’
           Move control lever from stop position till the control rack just moves forward. At this point, set the scale on the
           control lever adjusting device to ‘0’.

           Control lever in maximum position, check the following readings

            RPM                              1400                             1800
            C Tr                             min. 16 mm                       0



                                                           236

                                    CITS : Automotive - Mechanic Diesel  - Exercise 15.2
   248   249   250   251   252   253   254   255   256   257   258