Page 255 - CTS - Mechanic Diesel - TP
P. 255

MECHANIC DIESEL - CITS





                                 Fig 6


















                                           Adjusting the maximum speed stop screw


           7  Idling speed control

           Run the pump at 300 rpm and move the control lever till the control rack moves to 5.9-6.0 mm. The control lever
           position should be 14+4o.
           If the readings are not obtained, replace idling springs.



                                 Fig 7






















                                                   Idling speed setting




            RPM                              1400                             585-645
            C Tr                             min. 7.0                         2.0

           8  Torque control (torque control travel: 0.6±0.1 mm)
           Run the pump at 600 rpm, keep the control lever at maximum speed screw and adjust the tension of torque control
           spring by adjusting the threaded bush till the control rack travel is 9.69.8 mm. Check the following readings:

            RPM               600                   900                      1500-1630
            C Tr              9.6-9.8               9.2-9.4                  9.1

           If the readings are not obtained, replace torque control spring sleeve with different collar thickness (if the C. Tr. at
           full load is other than 9.1 mm, take only the difference in C.Tr. from 600-1400 грm).



                                                           238

                                    CITS : Automotive - Mechanic Diesel  - Exercise 15.2
   250   251   252   253   254   255   256   257   258   259   260