Page 255 - CTS - Mechanic Diesel - TP
P. 255
MECHANIC DIESEL - CITS
Fig 6
Adjusting the maximum speed stop screw
7 Idling speed control
Run the pump at 300 rpm and move the control lever till the control rack moves to 5.9-6.0 mm. The control lever
position should be 14+4o.
If the readings are not obtained, replace idling springs.
Fig 7
Idling speed setting
RPM 1400 585-645
C Tr min. 7.0 2.0
8 Torque control (torque control travel: 0.6±0.1 mm)
Run the pump at 600 rpm, keep the control lever at maximum speed screw and adjust the tension of torque control
spring by adjusting the threaded bush till the control rack travel is 9.69.8 mm. Check the following readings:
RPM 600 900 1500-1630
C Tr 9.6-9.8 9.2-9.4 9.1
If the readings are not obtained, replace torque control spring sleeve with different collar thickness (if the C. Tr. at
full load is other than 9.1 mm, take only the difference in C.Tr. from 600-1400 грm).
238
CITS : Automotive - Mechanic Diesel - Exercise 15.2