           The BOP hosts the following features:

           Speed, frequency, motor direction and current etc. displayed as required For direct control, the BOP is mounted
           directly on to the front panel of the inverter For “Quick Commissioning” of the inverter, the Getting Started Guide
           should be used. For other methods of commissioning, see the Operating Instructions or Reference Manual.

























           1  Change Direction : Changes the direction of rotation of the motor. Reverse is indicated by a mines (-) sign.

           2  Start Inverter: This button starts the inverter. This button is Disabled by default. To enable this button set P0700
              to 1.
           3  Stop Inverter: This button stops the motor in the time set in P1121(Ramp-downtime).

           4  Jog Motor: While the inverter has no output this button Causes the motor to start and run at the preset jog
              frequency. The inverter stops when the button is released.
           5  Access Parameters: Pressing this button allows the user to  access The parameters in the selected user
              access level.
           6  Decrease Value: Pressing this button decreases the displayed value. To change the frequency set point via the
              BOP set P1000=1 (when P0700 = 1).

           7  Increase Value: Pressing this button increases the displayed value. To change the frequency set point via the
              BOP set P1000=1 (when P0700 = 1).
           8  Functions:  This button can  be used to  view additional Information. See Section5.1.2 on page 42 of  the
              MICROMASTER 420 Operating Instructions.
           Changing parameters and settings using a‘BOP’/‘AOP’
           The following description shows how to change the parameter P1082. Use this description as a guide for setting
           any parameters using the ‘BOP’.

                                  Step                                       Result on display


            1  Press    to access parameters


            2  Press    until P0010 is displayed
               Press    to access P0010


            3  Value level Press    to set P0010=1Press
               To save and exit






                                                           342