Page 363 - Electronic Mechanic - TP - Volume - 2
P. 363

ELECTRONICS MECHANIC - CITS






                Green            Yellow        Priority Display            Drive Status Definitions

                                                                ROM Failure-Both LEDs Flashing same
             Flashing – R2    Flashing – R2          2
                                                                time
                                                                RAM Failure-Both LEDs Flashing
             Flashing – R2    Flashing – R2          3
                                                                Alternately
            R1 - Ontime900mSec.R2- Ontime300mSec.

                                            With Operator Panels (BOP&AOP)

           The following fault codes for the Basic Operator and Advanced Operator Panels indicate the status of the inverter:
           Over current (FaultF0001)


                              BOP/AOP Fault code      Status of MICROMASTER420 Inverter
                                      F0001           Over current

                                      F0002           Over voltage
                                      F0004           Inverter over temperature (internal PTC)
                                      F0011           Motor over temperature by I²t calculation


           Ramp up time set too short. Increase P1120 accordingly.
           Voltage boost too high. Reduce parameters P1310,P1311andP1312 to prevent excessive magnetization of the
           motor.
           Overvoltage (FaultF0002)

           Ramp down time set too short-IncreaseP1121accordingly.
           Result: Thus the Quick commissioning of MM-420 has been completed.








































                                                           346
                                    CITS : E & H - Electronics Mechanic  - Exercise 233
   358   359   360   361   362   363   364   365   366   367   368