Default Settings
Digital inputs Terminals Parameter Default operation
1 5 P0701=‘1’ ON right
2 6 P0702=‘12’ Reverse
3 7 P0703=‘9’ Fault Acknowledge
Output relay 10/11 P0731=’52.3’ Fault Indication
Analogue Output 12/13 P0771=’21’ Output Frequency
RESET Using P0010&P0970
When resetting the inverter P0010must be set to 30 (Factory Setting), it is then possible to set P0970 to‘1’.The
inverter will automatically reset all its parameters to their default settings.
§Denotes parameters that contain more detailed lists of possible settings for use in specific applications. Please
refer to the Reference Manual and Operating Instructions on the CD
*Motor related parameters–please refer to motor rating plate drawing.
Result: Thus the Default settings of AC Drive(MicroMaster-420) with Default settings have been successfully
completed.