           You can use the BOP for the following operations:
           •  Standalone commissioning

           •  Diagnosis
           •  Parameter access
           •  Parameter settings
           •  SD card operations

           •  Drive restart
                                        Commissioning in speed control mode (S)

            Step                 Description                                     Remarks

              1   Switch off the mains supply.
              2   Power  off  the  servo  drive  and  connect  it  to  The digital signals CWL, CCWL and EMGS must be
                  the  controller  (for  example,  SIMATIC  S7-200  kept at high level (1) to ensure normal operation.
                  SMART) with the signal cable.
                                                             Refer to "Standard application wirings (factory
                                                             setting)  (Page  73)"  and  "Connection  examples  with
                                                             PLCs (Page 77)".

              3   Power on the servo drive.
              4   Switch  to  the  speed  control  mode  by  setting  Refer to "Compound controls (Page 125)".
                  p29003=2.
              5   Restart the servo drive to apply the settings of
                  the speed control mode.