Job Sequence
TASK 1 : List the components,to operate Single Acting cylinder using 3/2 way valve
1 Identify the components and list using ISO 1219 symbol in the table.
The instructor shall arrange trainer board with components mentioned
Component Symbol
Pneumatic Source
Single Acting Cylinder
3/2 Way valve
FRL
TASK 2: Draw circuit diagram. (Fig 1)
Fig 1
TASK 3: Assemble circuit on the trainer board
1 Arrange component on trainer board as shown.
2 Connect source to FRL
3 Connect FRL to input port “1” of 3/2 Way valve.
4 Connec t output port “2” of 3/2 Way valve to input port of single acting cylinder.
5 Ensure proper connections.
170