           6   Supply air.

              Correct the assembly if air leaks through joints

           TASK 4: Check function of the circuit per the table

                  Action                       Expected Result               Confirm Result (Put )
                  Press Push Button            Piston moves forward
                  Release push Button          Piston retracts
           Conclusion
                  Conclusion drawn                                           Remarks

                  Motion of Single Acting cylinder can be c
                  ontrolled by3/2 Way valve.
           Connect tube using push in fitting

           1  Grip pull back ring. (Fig 2)

             Fig 2
















           2   Pull the ring. (Fig 3)

            Fig 3
















           3   Push the P U (poly (Urethene) tube into fitting. (Fig 4)

             Fig 4