Page 187 - CITS - Fitter Trade Practical - Volume -2
P. 187
FITTER - CITS
4 Push lock ring forward to lock. (Fig 5)
Fig 5
Construct a control circuit for the control of a d/a
pneumatic cylinder with momentry input signals
Objectives: At the end of this exercise you shall be able to
• select the components,to operate single acting cylinder using 5/2way valve
• draw circuit diagram
• check function of the circuit.
Requirements
Tool / Instrument / Equipment / Machines Material / Component
• Trainer board - 1 No. • P U Tube - as reqd.
• Pneumatic source - 1 No. • Paper - as reqd.
• Pencil - as reqd.
• Single Acting Cylinder - 1 No.
• 3/2 way valve - 1 No.
• FRL - 1 No.
Procedure
TASK 1:Select and list the components,to operate double acting cylinder using 5/2 way valve.
1 Identify the components and list using ISO 1219 symbol in the table.
The instructor shall arrange trainer board with components mentioned.
Component Symbol
Pneumatic Source
Single Acting Cylinder
3/2 Way valve
FRL
TASK 2: Draw circuit diagram (Fig 1)
172
CITS : C G & M - Fitter - Exercise 89