           EXERCISE 26 : Pipe welding - 45° branch joint MS pipe
                                     ø50mm and 3mm wall thickness in

                                     flat position (OAW)


            Objectives

           At the end of this exercise you shall be able to
           •  prepare the development of pipe for 45° branch joint
           •  cut and prepare the pipes as per dimensions
           •  tack and complete the welding by manipulating the torch and filler rod.












































           Procedure for development of 45° branch pipe: Refer Fig 1. Draw a centre line AB.
           Mark the points C, D, E and F taking the radius and the length of the given pipe with the centre line AB as
           reference line.
           On the line “CD” locate the position of the 45° branch pipe. This will be “G”.
           Draw a 45° angle at the point “G”.