           CI     =            Connector input, i.e. parameter selects the source of an analog signal

           CO     =           Connector output, i.e. parameter connects as an analog signal

           CO/BO =            Connector/Binector output, i.e. parameter connects as an analog signal and/or as a binary
                                 signal
           To make use of BiCo you will need access to the full parameter list. At this level many new parameter settings are
           possible, including BiCo functionality. BiCo functionality is a different, more flexible way of setting and combining
           input and output functions. It can be used in most cases in conjunction with the simple, level 2 settings.
           The BiCo system allows complex functions to be programmed. Boolean and mathematical relationships can be
           set up between inputs (digital, analog, serial etc.) and outputs (inverter current, frequency, analog output, relays,
           etc.).

           3  CStat
              Commissioning status of the parameter.
              Three states are possible:
              Commissioning      C
                         Run     U
              Ready to run       T

              This indicates when the parameter can be changed. One, two or all three states may be specified. If all three
              states are specified, this means that it is possible to change this parameter setting in all three inverter states
           4  P-Group

              Indicates the functional group of the particular.
              Parameter P0004 (parameter filter) acts as a filter and focuses access to parameters according to the functional
              group selected.
           5  Datatype

              The data types available are shown in the table below.

                                            Notation             Meaning
                                              U16             16-bit unsigned
                                              U32             32-bit unsigned

                                               I16             16-bit integer
                                               I32             32-bit integer
                                              Float            Floating point

           6  Active
              Indicates whether
              •  Immediately changes to the parameter values take effective immediately after they have been entered, or
              •  Confirm   the “P” button on the operator panel (BOP or AOP) must be pressed before the changes take
                 effect.
           7  Unit
              Indicates the unit of measure applicable to the parameter values
           8  QuickComm

              Indicates whether or not (Yes or No) a parameter can only be changed during quick commissioning, i.e. when
              P0010 (parameter groups for commissioning) is set to 1 (quick commissioning).