Page 349 - Electronic Mechanic - TP - Volume - 2
P. 349

ELECTRONICS MECHANIC - CITS





              ParNo             Parameter name                    ParNo             Parameter name
            r0034      CO: Motor temperature (i2t)              r1170      CO: Frequency setpoint after RFG
            r0036      CO:Inverter overload utilization         r1242      CO: Switch-on level of Vdc-max
            r0037      CO: Inverter temperature [°C]            r1315      CO: Total boost voltage
            r0039      CO: Energy consumpt. meter [kWh]         r1337      CO: V/f slip frequency
            r0067      CO: Act. output current limit            r1343      CO: Imax controller freq. output
            r0071      CO: Max. output voltage                  r1344      CO: Imax controller volt. output
            r0078      CO: Act. current Isq                     r1801      CO: Act. pulse frequency
            r0084      CO: Act. air gap flux                    r2015[4]   CO: PZD from BOP link (USS)
            r0086      CO: Act. active current                  r2018[4]   CO: PZD from COM link (USS)
            r0395      CO: Total stator resistance [%]          r2050[4]   CO: PZD from CB
            r0755      CO: Act. ADC after scal. [4000h]         r2110[4]   CO: Warning number
            r0947[8]   CO: Last fault code                      r2224      CO: Act. fixed PID setpoint
            r0948[12]  CO: Fault time                           r2250      CO: Output setpoint of PID-MOP
            r0949[8]   CO: Fault value                          r2260      CO: PID setpoint after PID-RFG
            r1024      CO: Act. fixed frequency                 r2262      CO: Filtered PID setp. after RFG
            r1050      CO: Act. Output freq. of the MOP         r2266      CO: PID filtered feedback
            r1078      CO: Total frequency setpoint             r2272      CO: PID scaled feedback
            r1079      CO: Selected frequency setpoint          r2273      CO: PID error
            r1114      CO: Freq. setp. after dir. ctrl.         r2294      CO: Act. PID output
            r1119      CO: Freq. setpoint before RFG


                                              Connector/Binector Output Parameters


             ParNo              Parameter name                    ParNo             Parameter name
            r0019      CO/BO: BOP control word                  r0722      CO/BO: Binary input values
            r0052      CO/BO: Act. status word 1                r0747      CO/BO: State of digital outputs
            r0053      CO/BO: Act. status word 2                r0751      CO/BO: Status word of ADC
            r0054      CO/BO: Act. control word 1               r0785      CO/BO: Status word of DAC
            r0055      CO/BO: Act. control word 2               r1204      CO/BO: Status word:Flying start
            r0056      CO/BO: Status of motor control           r2197      CO/BO: Monitoring word 1



           2  Parameter Description
              Note: Level 4 Parameters are not visible with BOP or AOP. They are only for service purposes.
                                                   Common parameters

            r0000     Drive display                                                        Min:   -
                                                    Datatype: U16      Unit: -             Def:   -
                      P-Group: ALWAYS                                                      Max:   -
                      Displays the user selected output as defined in P0005.
               Note:Pressing the “Fn” button for 2 seconds allows the user to view the values of DC link voltage,
               output frequency, output voltage, output current, and chosen r0000 setting (defined in P0005).







                                                           332
                                  CITS : E & H - Electronics Mechanic  - Exercise 227 - 230