Page 178 - CTS - Mechanic Diesel - TP
P. 178

MECHANIC DIESEL - CITS



           EXERCISE 9.6: Perform testing of Actuators


            Objectives

           At the end of this exercise you shall be able to
           •  test the Fuel pump relay and Radiator fan relay
           •  test the EGR valve
           •  test the Fuel injector.
           Requirements

           Tools/Instruments                                   Equipments/Machines

           •  Trainees tool kit                  - 1 No.       •  A light motor vehicle with CRDI Engine  - 1 No.
           •  Multimeter                         - 1 No.       Materials
           •  Fuel injector leak measuring pipes    - as reqd.  •  Tray                                        - 1 No.
           •  Scan Tool                          - 1 No.       •  Banian cloth                                   - 1 No.
           •  Oscilloscope 20 MHZ                - 1 No.       •  12V battery                              - 1 No.

            Procedure

           Test the fuel pump relay

           1  Turn off the Ignition key.
           2  Connect the scan tool to DLC and Turn On Ignition switch.
           3  Check the fuel pump operating sound is heard by actuating the scan tool actuation test. If the sound is not
              heard, go to the next step.

           4  Turn the Ignition switch off and Remove the fuel pump relay from fuse box.
           5  Check the continuity between terminal ‘3’ an ‘4’. If there is continuity shows replace the Relay.
           6  Connect a battery positive terminal to terminal ‘2’ of relay. Connect battery negative terminal to terminal 1 of
              relay. Check for continuity between Terminal “3” and “4”. If there is no continuity when relay is connected to
              the battery, replace relay.
           Test the Radiator Fan relay

           1  Turn off the Ignition key.
           2  Connect the scan tool to DLC and Turn On Ignition switch.
           3  Turn ignition switch ON.
           4  Check the cooling fan operates at low speed  by using  actuating the scan tool actuation test. If it  is not
              working, go to the next step.
           5  Check the cooling fan operates at high speed  by using  actuating the scan tool actuation test. If it  is not
              working, go to the next step.

           6  Turn the Ignition switch off and Remove the cooling fan relay from fuse box.
           7  Check the continuity between terminal ‘3’ an ‘4’. If there is continuity shows replace the Relay.
           8  Connect a battery positive terminal to terminal ‘2’ of relay. Connect battery negative terminal to terminal “1 “of
              relay. Check for continuity between Terminal “3” and “4”. If there is no continuity when relay is connected to
              the battery, replace relay.











                                                           161
   173   174   175   176   177   178   179   180   181   182   183