Page 174 - CTS - Mechanic Diesel - TP
P. 174
MECHANIC DIESEL - CITS
Sample test data for Axial Starters
If the lamp lights during any of these tests, the insulation is faulty.
SP5-12 BS5-12 BS5-24 SL5-24
Lock Torque TORQUE 3.8 kg.m 3.75 kg.m 4.6 kg.m 8.2 kg.m (min)
(281b-ft) (271b-ft) (33 1b - ft)
CURRENT 1400 Amps max. 900 Amps max. 780 Amps max. 1370 Amps max.
VOLTAGE 5 volts 5.5 volts 9.0 volts 10.5 volts
Running Torque TORQUE 1.66 kgm 1.53 kg-m 2.1 kg.m 3.5 kg.m
(121b-ft) (11 1b-ft) (15.2 1b-ft)
CURRENT 700 Amps max. 420 Amps max. 400 Amps max. 650 Amps max.
VOLTAGE 8.0 volts 8.0 volts 16.0 volts 18.8 volts
SPEED 1400-1600 rpm 1200 rpm 1450-1650 rpm 1200 rpm
Light Running CURRENT 140 Amps max. 60 Amps 70 Amps max. 120 Amps max.
VOLTAGE 11.6 volts 11.0 volts 24 volts 23 ± 0.5 volts
SPEED 3800-4200 rpm 2600 rpm 3800-4200 rpm 3500 rpm
157