Page 174 - CTS - Mechanic Diesel - TP
P. 174

MECHANIC DIESEL - CITS




                                            Sample  test data for Axial Starters
           If the lamp lights during any of these tests, the insulation is faulty.

                                                 SP5-12          BS5-12           BS5-24          SL5-24
              Lock Torque       TORQUE          3.8 kg.m        3.75 kg.m        4.6 kg.m     8.2 kg.m (min)
                                                 (281b-ft)       (271b-ft)       (33 1b - ft)
                               CURRENT       1400 Amps max.   900 Amps max.   780 Amps max.   1370 Amps max.

                               VOLTAGE           5 volts         5.5 volts        9.0 volts      10.5 volts
            Running Torque      TORQUE           1.66 kgm       1.53 kg-m        2.1 kg.m         3.5 kg.m
                                                 (121b-ft)       (11 1b-ft)     (15.2 1b-ft)
                               CURRENT       700 Amps max.    420 Amps max.   400 Amps max.    650 Amps max.
                               VOLTAGE           8.0 volts       8.0 volts       16.0 volts      18.8 volts
                                SPEED         1400-1600 rpm      1200 rpm     1450-1650 rpm      1200 rpm

            Light Running      CURRENT       140 Amps max.       60 Amps       70 Amps max.    120 Amps max.
                               VOLTAGE          11.6 volts       11.0 volts       24 volts      23 ± 0.5 volts
                                SPEED         3800-4200 rpm      2600 rpm     3800-4200 rpm      3500 rpm

























































                                                           157

                                    CITS : Automotive - Mechanic Diesel  - Exercise 9.3
   169   170   171   172   173   174   175   176   177   178   179