                                                                             MODULE 7 : GTAW

           EXERCISE 61: Set up and monitor GTAW welding

                                    machine & accessories



            Objectives

           At the end of this exercise you shall be able to
           •  identify the GTAW welding machine an accessories
           •  describe the welding technics of GTAW








































           Job Sequence

           •  The contact tip should be removed to facilitate easy flow of the wire from the Spiral and put in position into the
              Torch later.
           •  Start the welding machine after the machine is connected to the 3 phase supply mains.
           •  15 © NIMI, Not to be republished Connect the welding torch to the positive terminal.
           •  The positive terminal influences deeper, wider weld penetration with a good ripple formation. Connecting the
              heater, regulator and flow meter:
           •  The inlet end of the inert gas heater is connected to the inert in cylinder.
           •  The heater should be connected to either 110V supply from the welding machine (or) 230V supply from the
              mains.
           •  This will help to avoid ice forming (freezing) of the inert gas at regulator and flow meter.
           •  Fix a twostage regulator using a flat spanner to the outlet end of the gas heater and ensure proper functioning
              of the dial gauges.