Page 226 - CITS - Fitter Trade Pactical - Volume - 2
P. 226

FITTER - CITS


                                                         Table 1
                                                     Data for cutting

                           Diameter of cutting       Thickness         Cutting
                           oxygen orifice            of steel          oxygen
                           nozzle                    plate             pressure

                                 (1)                    (2)                   (3)
                                 mm                     mm                 kgf/cm2
                                 0.8                   3.6                  1.0 - 1.4
                                 1.2                   6.19                 1.4 - 2.1

                                 1.6                   19 - 100             2.1 - 4.2
                                 2.0                   100 - 150            4.2 - 4.6
                                 2.4                   150 - 200            4.6 - 4.9
                                 2.8                   200 - 250            4.9 - 5.5

                                 3.2                   250 - 300            5.5 - 5.6


           Acetylene pressure should be 0.15 kgf/cm2 for all thickness of plates.
           Select ø1.2 mm (orifice)  cutting nozzle for cutting a 10 mm thick plate.
           Set 1.6 kgf/sq.cm pressure for the cutting oxygen and
           0.15 kgf/sq.cm pressure for the acetylene gas.
           Ensure safety apparel is worn.

           Fix the cutting nozzle into the cutting blowpipe correctly. (Fig 3)

              Fig 3
























           Check for leakage in the blowpipe connections of oxygen and actylene gas lines.
           Adjust the neutral flame for preheating. (Fig 4)
           Ensure that the flame adjustment is not disturbed while operating the cutting oxygen lever.











                                                           211

                                           CITS : C G & M - Fitter - Exercise 54
   221   222   223   224   225   226   227   228   229   230   231